45
/O Open I2C Connection
/(*)Rn Master Rx Message *=No Stop
/S(text) Slave Tx Message
/(*)T(text) Master Tx Message *=No Stop
/Un Set I2C Bus Time-oUt in msec 0=Disable)
/V Display Firmware Version (Major XX.XX Minor)
/X[...]... Extended Cmds (See Prompt or User's Guide)
/Y Display Tx bYte Count
Interrupt Signal Control/Status
The INT signal allows the iPort/AFM to participate in INT master and/or slave
communications.
Control
Command: /N0[CR] Disable Monitor
/N1[CR] Enable Monitor
/NA[CR] Assert INT Signal
/NR[CR] Release INT Signal
Status
Command: /N[CR] Status
Response: /NSA INT Asserted
/NSR INT Released
Response: * 'iPort/AFM Ready
Default Setting: /N0, /NR
Open I
2
C Connection
Activates iPort/AFM as an active device on the I
2
C Bus.
Command: /O[CR] 'Open I
2
C Connection
Response: /OCC[CR] 'Open Connection Complete
Default Setting: Closed
Master Read Message
This command causes iPort/AFM to read the specified number of data bytes from
the currently selected Destination I
2
C Slave Address with or without generating an
I
2
C Stop condition after the last byte is received.
Komentáře k této Příručce